Air Tightness Testing

Testing for Air Tightness

Air tightness testing is a recognised method of measuring the extent to which air is lost through leaks in the building fabric. It is sometimes referred to as air leakage testing or air pressure testing. When testing for air tightness the pressure differential is measured across the envelope of the building be means of a large fan installed temporarily sealed and a range of static pressures and environmental readings are taken. The fan is switched on and the air pressure in the property is gradually increased or decreased and the differential pressure is recorded at each step. The total air flow required to achieve a pressure differential of 50 Pa is calculated and divided by the total building envelope area to provide the leakage rate in m3/hr/m2.

Air_Tightness_Testing

 On each development air tightness testing should be carried out on three units of each dwelling type or 50% of all the instances of that dwelling type, whichever is less. A block of flats should be treated as a separate development irrespective of the number of blocks on the site.

Depending on the size of the property, the duration of the air tightness test should take no longer than 2 hours with the air tightness test certificate issued some 2 days later.

It is best to make sure that the building is fully prepared for the air tightness test, in most cases the main areas of air leakage are through penetrations in the kitchen and/or utility room and through penetrations in the bathrooms and cloak rooms. Other common air leakage paths are through the wall/floor junction, light fittings and boilers rooms and service cupboards.

Our fan systems are compact, discreet and fit simply into a personnel door. The system can easily be transported through areas of limited access or up to high level areas. It is for this reason that many companies working in busy city centres utilise our expertise and equipment. We are able to eliminate the site disruption caused by the larger trailer type testing equipment. Work can also continue inside the building whilst the air leakage test is being carried out.

In the event of a building failing an air tightness test,  we can offer smoke testing, which highlights the areas of leakage in the building fabric. We can then undertake a full written and photographic survey as reference for your site management and relevant subcontractors. We will also offer free advice on the best method to seal any leaking areas. The main benefits of this are:

  • Air leakage is quickly identified in the event of a test failure
  • Remedial works can start straight away
  • Practical completion can be achieved more quickly

If you require air tightness testing or domestic ventilation testing, we have the knowledge and experience to ensure your building passes first time. If you require more information please contact me direct on 07775 623464 or e-mail me at: darren@airpressuretesting.net